CCW 5
CCW 5IndustrialCorrosion inhibitor for closed cooling systems — diesel engines, caterpillars and heavy earthmoving equipment — with a built-in indicator.
Available in25 L200 L
Available from: Windhoek & Walvis Bay agent
Own Cernol formulations — manufactured in Windhoek
CCW 5 closed-circuit corrosion inhibitor with its built-in indicator, and Chemicide No 7 diesel-tank biocide — Cernol’s treatment chemistry protects the cooling circuits and fuel tanks of Namibian mines, fleets and vessels running on the country’s hard, scarce water and unforgiving heat.


Corrosion inhibitor for closed cooling systems — diesel engines, caterpillars and heavy earthmoving equipment — with a built-in indicator.
Available in25 L200 L
Available from: Windhoek & Walvis Bay agent
Look at it — CCW 5 carries a built-in indicator that colours the coolant while the inhibitor charge is active. When the colour fades, top up. That one design choice is why mines run it across earthmoving fleets: a fitter does a visual check at service time instead of sending samples away. It protects the mixed metals of diesel-engine jackets and heavy-equipment cooling circuits against corrosion, which is the dominant failure mode in closed systems.
Because they guard the two liquid systems every diesel machine depends on: the closed cooling circuit and the fuel tank. Namibian heat cycles condense water into both — in the coolant it drives corrosion, at the fuel–water interface it feeds the microbial growth that blocks filters. CCW 5 films the cooling circuit’s metals; Chemicide No 7 sterilises the tank. Fleets that dose both stop having either class of breakdown.
Anything with a closed cooling circuit that must not fail: haul trucks, caterpillars and earthmoving plant (the segmentation lists them verbatim), generators, fishing-boat engines, and older fleet vehicles whose radiators have already had a Magnus 614 descale. Dose to circuit volume, check the indicator colour at every service, and top up when it fades — the whole programme fits inside an operator’s daily walk-around.
Yes — the fishing segmentation lists CCW 5 for boats’ closed cooling and Chemicide No 7 for the fuel tanks, and both move through the Walvis Bay agent with quayside delivery by arrangement. Dose the biocide before a lay-up rather than after it, and change filters after the first treatment of a dirty system. Tell us which circuit you are treating — sea-water and fresh-water circuits are different disciplines — and we will match the product.
Supplied from the Windhoek factory and the Walvis Bay agent, with trade accounts for resellers and volume users.